  1. From plan to running site in 6 to 8 months.

    ModFlex is a modular data center for high-density AI and HPC. The units are steel-frame buildings, designed to the size each project needs and made in the factory while the site is prepared.

    Send an enquirySee how it is built

    Late at night, a designer in a black ModFlex T-shirt sits at his desk in a dark room. On his screen is the plan of a ModFlex site, drawn in a CAD program.
    Illustration
  2. 1Plans on paper

    Every site starts as a drawing. No unit has a fixed size: each steel frame is drawn to the length, width and height its project needs, around the racks, their power and their cooling.

    In the picture: The plan of a ModFlex site drawn in black ink: two rows of units, a hallway between them, the power yard, the cooler yard and the road.

    Illustration
  3. 2Site check

    We check the plot: the grid connection, fiber, and road access for the low-loaders.

    In the picture: The road and the grid line that are already there appear on the drawing. Stakes mark the corners of the plot.

    Illustration
  4. 3Power in

    Groundwork comes first. The footings are poured, the transformers are placed and the power is brought in.

    In the picture: A concrete slab with rows of footings. Two transformers and two power units stand beside it, inside a fence.

    Illustration
  5. 4Factory

    At the same time, the factory builds the units on steel frames.

    They are buildings designed for the project. They are not shipping containers.

    In the picture: Inside the factory: steel frames of ModFlex units on an assembly line under a gantry crane.

    Illustration
  6. 5Transport

    The units come by road on low-loaders. A crane lifts them onto their footings, side by side.

    In the picture: A crane sets units side by side while a low-loader waits on the road with the next one.

    Illustration
  7. 6Cladding

    With the units set, the cladding goes on. It is made to order for the site: here light metal panels below and timber slats above.

    In the picture: Cladding goes on the two white spaces: light metal panels on the lower level and timber slats on the level above.

    Illustration
  8. 7Fit-out and commissioning

    Power, cooling and racks go in. Cooling is air, direct liquid, or a hybrid of both, chosen for the project.

    Then the site is tested, and the lights come on.

    In the picture: The finished site: dry coolers in their yard, pipes to the building, the ModFlex name on the wall and light lines along the cladding.

    Illustration
  9. Then the lights come on.

    Illustration of a typical deployment. It does not show a real site.

A hallway in the middle, a white space on each side.

In most projects the units stand side by side and form two white spaces. A walking hallway runs between them.

A ModFlex building with the roof left off: a hallway runs through the middle, and on each side a white space holds rows of racks with cable trays and cooling pipes above them.
Illustration. The roof is left off to show the rooms.
The running ModFlex site at dusk: light panels below and timber slats above, white light lines along the walls, the ModFlex name lit on the timber, warm light behind the louvres.

Then the lights come on.

Illustration of a typical deployment. It does not show a real site.

Modular and flexible.

That is what the name stands for. A ModFlex unit has no fixed size: its steel frame is designed to the length, width and height the project needs, and the units are combined into the building the site calls for.

Four ModFlex builds side by side at one scale: a single unit in timber slats, a short row of three units in light metal, two white spaces in light metal and timber, and a larger hall in zinc and timber.
  • The cooler

    On a single unit or a short row the cooler sits on the roof. Cooling is air, direct liquid, or a hybrid of both, chosen for the project.

  • Cladding

    Made to order for the site: light metal panels, timber slats, zinc, or a mix.

  • Concrete footings

    Here the units stand on concrete footings. Not every site needs them.

  • The cooler

    On a single unit or a short row the cooler sits on the roof. Cooling is air, direct liquid, or a hybrid of both, chosen for the project.

  • The steel frame

    Under the cladding every unit is a steel frame, built in the factory to the size the project needs. Move the pointer to look around.

  • The level above

    Above the IT level runs a second level for pipes and cables.

  • The steel frame

    Under the cladding every unit is a steel frame, built in the factory to the size the project needs. Move the pointer to look around.

  • The hallway

    A walking hallway in the middle, a white space on each side.

  • Concrete footings

    Here the units stand on concrete footings. Not every site needs them.

  • Inside

    Racks stand in the white spaces, with the walking hallway between them. Move the pointer to look around.

  • No fixed size

    Longer, wider, taller: each steel frame is designed to the length, width and height the project needs.

  • Inside

    Racks stand in the white spaces, with the walking hallway between them. Move the pointer to look around.

  • Cladding

    Made to order for the site: light metal panels, timber slats, zinc, or a mix.

  1. A single unit

    One unit with its cooler on top, for smaller deployments. Here in timber slats.

  2. A short row

    A few shorter units side by side on one level. Here in light metal panels.

  3. Two white spaces

    Units side by side, a walking hallway in the middle and a white space on each side. This is how most ModFlex sites are built, and it is the build in the story above.

  4. Longer, wider, taller

    The same idea with larger units and more of them. Capacity can be added in stages, unit by unit.

Point at a mark to look closer. Tap a mark to look closer, swipe for the next build. Four examples at one scale. Illustration. These are not a catalogue: every project gets its own design.

The cladding is made to order as well: light metal panels, timber slats in the Scandinavian way, or a mix of both. Light colours take up less of the sun's heat than dark ones, which suits a data center.

A single ModFlex unit close up: timber slats with the ModFlex name, the cooler with its fans on top, doors with steel steps at both ends.
A single unit in timber, close up. Illustration.

Particulars

Scope
The building, the power and the cooling.
Sizes
No fixed unit size. Each steel frame is designed to the length, width and height the project needs.
Cladding
Made to order for the site, for example light metal panels or timber slats.
Cooling
Air, direct liquid cooling, or a hybrid of both. Chosen per project.
Platforms
The design starts from the IT equipment, so the list is open. Examples: NVIDIA B300, GB300 NVL72 and Vera Rubin, AMD Instinct MI355X and AMD Helios, and the generations that follow them.
Capacity
Sized per project and added in stages, unit by unit. One published example: 16 GB300 NVL72 racks at 150 kW each, 2.4 MW of IT load.
Delivery
6 to 8 months, in five phases. Factory build and site work run at the same time.
Team
More than ten years of work with IT equipment and several years in AI infrastructure. The design team includes engineers accredited by the Uptime Institute as Accredited Tier Specialists.
Company
Eliovp BV, Sint-Gillis-Waas, Belgium. Founded in 2017.

Many data center builders come from construction, or from older data centers built before AI. This team comes from the IT equipment, and designs the facility around what that equipment needs.

Tell us about your site.

Where it is, how much power it has, and what you want to run.

Send an enquiry